← Sheet Metal Bend Allowance Calculator THE SPOOL LIST

5 mm 6061-T6 aluminium bend allowance and bend deduction

At a 90° bend with an inside radius of 3 × thickness (15.00 mm / 0.5906 in) and K = 0.40, 5 mm 6061-T6 aluminium (5 mm / 0.1969 in) has a bend allowance of 26.70 mm (1.0513 in) and a bend deduction of 13.30 mm (0.5235 in).

Bend allowance at 90° (R = 3T, K 0.40)
26.70 mm
1.0513 in · bend deduction 13.30 mm
Thickness (T)
5 mm / 0.1969 in
Inside radius used (R)
15.00 mm (0.5906 in) = 3 × T
K-factor
0.40 (typical air bending, approximate)
Bend deduction at 90°
13.30 mm (0.5235 in)
Outside setback at 90°
20.00 mm (0.7874 in)
Typical minimum inside radius
2–3 × T typical; 3 × T or more on plate
5 mm 6061-T6 aluminium: bend allowance (BA) and bend deduction (BD) by bend angle, R = 3T (15.00 mm / 0.5906 in), K = 0.40
Bend angleIncluded angleBA (mm)BD (mm)BA (in)BD (in)
30°150°8.901.820.35040.0715
45°135°13.353.220.52570.1266
60°120°17.805.290.70090.2083
90°90°26.7013.301.05130.5235
120°60°35.6033.681.40181.3259
135°45°40.0656.511.57702.2249
5 mm 6061-T6 aluminium: BA and BD at 90° for different inside radii (K from the generic air-bending table)
Inside radiusR / TK-factorBA (mm)BD (mm)BA (in)BD (in)
10.00 mm20.4018.8511.150.74210.4390
12.50 mm2.50.4022.7812.220.89670.4812
15.00 mm30.4026.7013.301.05130.5235
20.00 mm40.5035.3414.661.39150.5771
25.00 mm50.5043.2016.801.70070.6615

Practical notes

The angle in these formulas is the bend angle — how far the flange turns away from flat. The included angle between the two flanges is 180° minus the bend angle, so a 90° bend is also 90° included, but a 135° bend leaves a 45° included angle.

K-factor values here come from a generic air-bending table that depends on R/T (about 0.33 below R = T, 0.40 from T to 3T, 0.50 above 3T for 6061-T6 aluminium). They are approximations: tooling, die width, grain and temper all shift the neutral axis. Bend a test strip, measure the flanges and back-calculate K before cutting a production run.

A V-die opening of about 8 × T (40.00 mm / 1.5748 in) is the usual starting point. In air bending the inside radius forms at roughly 13–15% of the die opening for 6061-T6 aluminium, so the radius you actually get depends on the die more than the punch — recompute with that radius if it differs from the R = 3T used above.

Springback for 6061-T6 aluminium at modest radii is typically about 2–5°, increasing as R/T grows; overbend to compensate. It changes the angle, not the bend allowance calculation.

6061-T6 is the least formable alloy here and cracks on the outside of tight bends; 2–3 × T is a typical minimum inside radius, and thicker plate often needs 3 × T or more. If the part needs a tight bend, consider 5052-H32, or bending 6061 in the O or T4 temper and heat-treating afterwards. Bend across the rolling direction where possible and inspect the outside of the bend for orange peel or cracks.

At 5 mm, many shops will not bend 6061-T6 tighter than about 3 × T (15.00 mm / 0.5906 in), which is why this page uses R = 3T; confirm the radius with your fabricator before finalising the flat pattern.

At 5.00 mm thickness, check press-brake tonnage and minimum flange length (roughly half the V-die opening plus a margin, about 22.50 mm / 0.8858 in with an 8 × T die) before committing to the design.

FAQ

What is the bend deduction for 5 mm 6061-T6 aluminium at 90°?

With R = 3T (15.00 mm / 0.5906 in) and K = 0.40, the bend deduction is 13.30 mm (0.5235 in). For a part with two 50 mm flanges measured to the outside, the flat blank is 50 mm + 50 mm − 13.30 mm = 86.70 mm.

What K-factor should I use for 5 mm 6061-T6 aluminium?

For air bending 6061-T6 aluminium at R = 3T, a K-factor of about 0.40 is a typical starting value; below R = T it drops to about 0.33, and above 3 × T it approaches 0.50. Real values depend on tooling and material lot, so confirm with a test bend.

Can 5 mm 6061-T6 aluminium be bent with a tight radius?

Not reliably. 6061-T6 tends to crack on the outside of tight bends; 2–3 × T is a typical minimum inside radius, and thicker plate often needs 3 × T or more. This page uses R = 3 × T (15.00 mm / 0.5906 in) for that reason. For tighter bends use 5052-H32 or bend 6061 in the O/T4 temper and heat-treat afterwards.

Is the angle in the bend allowance formula the bend angle or the included angle?

It is the bend angle, the amount the flange is turned from flat. If your drawing gives the included angle between flanges, use 180° minus that value: a 45° included angle is a 135° bend.

Sources: Bend allowance formula BA = A·(π/180)·(R + K·T); bend deduction BD = 2·tan(A/2)·(R + T) − BA (Machinery's Handbook, sheet metal bending) · Generic air-bending K-factor table by R/T (approximate)